Conversion of the angular position of the shafts of

mechanical primary detectors into a load-independent

direct current signal

High precision

— Non-linearity < 1 %

Simple conversion from 2, 3 or 4-wire operation

(only 2-wire circuit in the case of devices with

explosion protection)


Options

— Electrical isolation between output and power supply

— Marine version with German Lloyd approval

— Intrinsically safe version for operation in Zone 1

— Limitation of superimposed interference voltage peaks

— Plug connection Han 7 D


Version TGE 5, TGE 5-Ex for attachment to

— Pressure gauges (with mounting hardware)

— Scales etc.

Version TGM 5, TGM 5-Ex for attachment to shafts

— In heavy machinery

— On ships etc.

Version TGU 5, TGU 5-Ex for installation in

— Pressure gauges

— Rotameters


Installation in systems with very high mechanical and

climatic stress

The customer’s specific adjustments are effected at the

factory, but can be changed subsequently


Input (see ordering information for measuring range)

Zero: Approx. ± 5 % adjustable (referred to the output span)

Shaft: can be freely rotated

Output and power supply

Non-linearity

< 1 % (referred to the output span)

TGE 5, TGM 5 (measuring range < 90°):

< 0.5 % (referred to the output span)

Response time: < 50 ms (jump 0 %...100 %)

Long-term influence: < 0.2 % / year

Residual ripple (peak-peak)

Output signal < 1 %

Power supply < 1.5 V

General and safety data

Environment conditions

See table 2 for application class

Ambient temperature: -25... +80 °C

Transportation and storage temperature: -40... +80 °C

Relative atmospheric humidity

TGE 5: < 75 % annual average, condensing perm., occasional

TGM 5: < 90 % annual average, condensing permitted

TGU 5: < 75 % annual average, condensing perm., occasional

Mechanical stress capabilities

Tested to DIN IEC 68-2-27 and 68-2-6

Impact: 50 g/11 ms

Vibration: 5 g/± 10 mm/5...150 Hz

TGU 5

Interference proof acc. to NAMUR Recommendation for industrial

standard in 2-wire circuit

TGE 5, TGM 5

Interference immunity acc. to NAMUR Recommendation for

industrial standard (surge 1.2/50 1.5 kV). Devices with explosion

protection (Ex devices) are only operated in 2-wire circuit.

Connection, housing, mounting and safety

TGE 5, TGE 5-Ex, TGM 5, TGM 5-Ex, TGU 5, TGU 5-Ex

Electrical connections

Screw terminals for 2.5 mm²

or plug connection Han 7 D (not for Ex)

TGU 5, TGU 5-Ex

4-conductor ribbon cable 150 mm long

Mounting orientation: any

Test voltage to DIN VDE 0411: 0.5 kV

Material of housing

Salt-water-proof cast aluminium

Surface anodized

TGE 5, TGE 5-Ex, TGU 5, TGU 5-Ex: plastic cover

Weight

TGE 5 approx. 0.5 kg

TGM 5 approx. 2.6 kg

TGU 5 approx. 0.2 kg